Fast Response in Critical Volumes
Gas extinguishing systems are a fast-acting and effective solution for protecting valuable equipment, process-critical spaces and flammable liquids.
Clean Agent Systems
These systems, consisting of halocarbon and ketone class gases, are an effective solution for the protection of single or multiple volumes over a cylinder center. These systems, which keep the fire damage at the lowest level by carrying the extinguishing agent to the volume within 10 seconds, have no effect on global warming. When properly designed and applied, it can also be used in places with personnel. There are different pressure options as 25, 42, 50 and 70 bar.
Area of Use
Electric volumes, flammable liquid storage, museums etc.
Advantages
Compact, fast installation, ease of operation
Certification
FM, UL, VdS, LPCB, CE
References
Inert Systems
These systems, which are established with Argon, Nitrogen and Carbon Dioxide gases in the atmosphere, are very effective solutions for the protection of large volumes. These systems, which show high performance at long distances and heights with their high pressure (200/300 bar) options, do not have a negative environmental impact because they are natural gases. In the volumes protected by these systems, relief dampers are used for structural safety.
Area of Use
Archive buildings, museums, battery rooms, electrical volumes
Advantages
Economical, easy to refill, long distance protection
Certification
VdS, UL, FM, LPCB
References
C02 Systems
Carbon dioxide extinguishing systems, which have the feature of high amount of cooling and removing oxygen from the environment, have a wide range of usage areas. These systems, which can also be used in cases where there are openings that cannot be closed, have features that can protect a volume completely, as well as directly protect sensitive equipment locally. Maximum safety precautions (odorizing device, delay and shut-off valve) must be taken in the volumes where they are installed in accordance with the regulations.
Area of Use
Transformers, generators, electrical volumes, production machinery
Advantages
Low filling costs, fast assembly, ease of operation
Certification
VdS, UL, FM
References
Cabinet Fire Protection
In cases where volumetric protection is not possible, electrical cabinets and panels can be protected directly with gas extinguishing systems. These systems, which have very small dimensions, can be positioned near the relevant panel and cabinet and can provide extinguishing with a flexible hose or a steel pipeline. These systems are presented in two separate categories, directly and indirectly. While detection and extinguishing are done with the same equipment in directly applied systems, a separate detection line and extinguishing line are used in indirect systems.
Area of Use
Electrical cabinets, switchboards, server cabinets etc.
Advantages
Ease of installation, practical, ease of maintenance, economical
Certification
LPCB, UL, FM, VdS
References
Room Integrity Test
In order for the system to extinguish with full performance in the volumes where gas extinguishing systems are installed, the space must meet certain sealing requirements. With the pressurization system installed on the door of the room, the air pressure in the indoor environment is increased. With the computer software, the losses over time are recorded and the sealing level of the space is checked. By detecting and closing the leaks, it is aimed to reach the desired level of impermeability.
Area of Use
All volumes with clean gas extinguishing, CO2 and inert gas extinguishing
Advantages
Pinpoint detection of leaks, detailed reporting and repeatable
Certification
UL, CE
References
Have questions? Our Fire Engineers are here to give you the best support!
Contact us for all your questions and information requests. Our representatives will get back to you as soon as possible.