Water Based Suppression Systems

Automatic Sprinkler Systems

The most common fire extinguishing and control systems that have provided successful protection in many fire cases with their wide usage areas.

Wet Pipe Sprinkler Systems

These systems, where the water pressurized by the fire pump system is kept ready for fire intervention in the installation, works on the basis of the sprinkler head being active at the preferred temperature. Wet pipe systems can be used in volumes with +4° ambient temperature or can be used with antifreeze in areas where there is a risk of freezing. Wet systems must be carefully tested and monitored for plumbing leaks, as they are kept pressurized.

Offices, warehouses, production areas, workshops, etc.

Flexible application, economical, easy to maintain, fast response

FM, UL, VdS, LPCB, CE

References

Dry Pipe Sprinkler Systems

Unlike wet sprinkler systems, in this type of systems, pressurized air/nitrogen is used instead of extinguishing water in pipe installation. Dry pipe systems, which are preferred in cases where the temperature value of the protected volume is lower than +4°, provides comprehensive protection for cold spaces. When the ceiling temperature in the protected volume reaches the selected degree of the sprinkler head, it is aimed that the air exits the installation first and the water reaches the sprinkler in the specified time.

Loading ramps, outdoor warehouses, cold storages, etc.

Prevention of water damage, long life piping, ease of application

FM, UL, VdS, LPCB, CE

References

Deluge Sprinkler Systems

Deluge systems, which can be used for cooling and extinguishing purposes, are designed on the basis of an intensive application at the same time in the design area in the protected volume. It is preferred in cases where the spread rate of fire and combustible material load is high. There is no extinguishing fluid in the installation and the sprinkler heads are used with open ends. Caps and covers suitable for ambient conditions are used to protect the installation and sprinkler heads. It can be triggered by detection or pilot sprinkler line.

Transformers, compartments, production areas, above ground tanks etc.

Simultaneous activation, can be used in severe conditions, fast protection

FM, UL, VdS, LPCB, CE

References

Pre-Action Sprinkler Systems

These systems, which are generally used to prevent water damage due to plumbing leaks and accidental opening of the sprinkler glass, can be used as single or double locking. Pressurized air is kept in the piping in the place. In these systems, which can be used as pneumatic and / or electrically activated according to the conditions of the location, in case of verification, it opens the control valve and allows the water to reach the sprinkler. Thus, the system is activated only when there is a confirmed fire case in the environment.

Warehouses, production areas, cold spaces, electrical rooms

System security, water damage prevention, long-lasting installation

FM, UL, VdS, LPCB, CE

References

Fire Pumps

Fire pumps, which are the heart of all systems in the fight against fire, ensure that the water needed is pressurized to the fire system pipe network. Fire pumps, which are offered with 4 different options as horizontal shaft, vertical shaft, turbine and end-suction, can be used as diesel driven or electric motor depending on the need. Preparing the fire pump room installation and fire water tank capacity according to the design criteria specified in the regulations is critical for the correct operation of the system.

Hydrant, cabinet and sprinkler etc. In all businesses with fire systems installed

Uninterrupted protection, redundant system, fully automatic use

UL, FM, NEMA

References

Manual Protection Measures

These systems, which were established to support fully automatic systems, can also be used for early intervention.

Outdoor Hose System (Hydrant)

The hydrant and hose systems installed in accordance with the hazard class of the facilities are a critical safety precaution for authorized personnel and firefighters in case of fire. These systems, which can be installed with underground or above-ground piping according to the project requirements, keep the structures in the business and the facility safe against fire cases that may occur in the outdoor area. Firefighters can also perform indoor interventions with these equipments.

Factories, warehouses, power plants, etc.

Direct and fast intervention, different discharge heads

TSE, CE, TS EN

References

Monitor Systems

These equipment, which are used to respond to the fire from a safe distance, can be offered as automatic and manually controlled. Monitor applications, which are an effective method for protecting equipment or raw materials in open environments, can be used with different throw options depending on the type of fire. Parameters such as distance, wind, open flame, and temperature should be considered when designing the monitor application. Fire monitors are also used in some cases for cooling and fire containment.

Tank yards, open air warehouses, loading stations, airports

Safe distance intervention, wide angle protection

UL, FM, VdS, NEMA, CE

References

Indoor Hose System (Fire Cabinets)

Fire cabinet and fire brigade valve system installed in closed areas is an effective method used to control or extinguish small fires by authorized personnel in the enterprise. The fire cabinet system, which allows different interventions according to the type of fire with its throwing heads, should be positioned at the intervals specified in the regulation. The status of the fire cabinet installation should be monitored by valve monitoring and flow switch.

All industrial facilities and businesses with legal obligations

Ease of use, quick response, access to the source of the fire

TSE, CE, TS EN

References

Have questions? Our Fire Engineers are here to give you the best support!

Contact us for all your questions and information requests. Our representatives will get back to you as soon as possible.